Standards for Offshore & Marine Cables
BS | British Standard Institution |
BS 5266-1 | Emergency lighting. Code of practice for the emergency lighting of premises |
BS 5839-1 | Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance |
BS 5839-6 | Fire detection and fire alarm systems for buildings. Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings |
BS 5839-8 | Fire detection and fire alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of voice alarm systems |
BS 5839-9 | Fire detection and alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
BS 6387 | Specification for performance requirements for cables required to maintain circuit integrity under fire conditions |
BS 7211 | Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire |
BS 7346-6 | Components for smoke and heat control systems. Specifications for cable systems |
BS 7629-1 | Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire. Multicore and multipair cables |
BS 7917 | Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed offshore units - RequireInents and test Inethods |
BS 7846 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 8434-2 | Methods of test for assessment of the fire integrity of electric cables. Test for unprotected small cables for use in emergency circuits. |
BS EN 50200 with a 930° flame and with water spray | |
BS 8491 | Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems |
BS 8519 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice. |
CEI | Comitato Elettrotecnico Italiano |
CEI 20-11 / EN 50363 | Insulating, sheathing and covering materials for low voltage energy cables |
CEI 20-36/2-1 | Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV |
CEI 20-45 | Fire resistant elastomeric insulated cables, halogen free (LSOH) with rated voltage Uo/U 0.6/1 kV |
DIN | Deutsches Institut fur Normung |
DIN 4102 | Fire behaviour of building materials and building components - Part 12: Circuit integrity maintenance of electric cable systems; requirements and testing |
EN | European Norm |
EN 50200 | Methods of test for resistance to fire of unprotected small cables for use in emergency circuit |
EN 50266 | Test for vertical flame spread of vertically-mounted bunched wires and cables |
EN 50267/2-1 | Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
EN 50267/2-2 | Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity |
EN 50288-7 | Sectional specification for instrumentation and control cables |
EN 50362 | Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits |
EN 50363 | Insulating, sheathing and covering materials for low voltage energy cables |
EN 60228 | Conductors of insulated cables |
EN 60332-1 | Test for vertical flame propagation for a single insulated wire or cable |
EN 60332-2 | Test for vertical flame propagation for a single small insulated wire or cable |
EN 60332-3 | Test for vertical flame spread of vertically-mounted bunched wires or cables |
EN 61034 | Measurement of smoke density of cables burning under defined conditions |
IEC | International Electrotechnical Commission |
IEC 60092-350 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 60092-351 | Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables |
IEC 60092-352 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
IEC 60092-353 | Electrical installations in ships - Part 353: Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1 kV and 3 kV; Amendment 1 |
IEC 60092-354 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<(Index)m> = 7,2 kV) up to 30 kV (U<(Index)m> = 36 kV) |
IEC 60092-356 | |
IEC 60092-359 | Electrical installations in ships - Part 359: Sheathing materials for shipboard power and telecommunication cables |
IEC 60092-375 | Shipboard telecommunication cables and radio-frequency cables - general instrumentation, control and communication cables |
IEC 60092-376 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60228 | Conductors of insulated cables - Guide to the dimensional limits of circular connectors |
IEC 60331 | Test for electrical cables under fire conditions. Circuit integrity. |
IEC 60332-1 | Tests on electric and optical fibre cables under fire conditions -Test for vertical flame propagation for a single insulated wire or cable |
IEC 60332-3 | Test on electric cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables |
IEC 60502-1 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)IEC 60754-1Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
IEC 60754-2 | Determination of degree of acidity (corrosivity) of gases by measuring pH and conducivity |
IEC 60793-1 | Optical fibres |
IEC 60794-1 | Optical fibre cables |
IEC 61034-2 | Measurement of smoke density of electric cables burning under defined conditions (LT) |
JIS | Japanese Standard |
JIS C 3410 | Cables and flexible cords for electrical equipment of ships |
NBN | Norme Belge |
NEK 606 | Cables for offshore installations- halogen free and/or mud resistant |
NBN C 30-004 | Fire resistance of electical cables - Classification and test methods |
NBN 713-020 | Fire resistance of building materials |
NF | Norme Française |
NF-C-32-070 | Insulated cables and flexible cords for installations - Classification tests on cables and cords with respect to their behaviour to fire |
SS | Singapore Standard |
SS 299 part 1 | Fire resistant cables - Performance requirements for cables required to maintain circuit integrity under fire conditions |
VG 95218-29 | LWDC These cables are transversally water blocked up to a pressure of 100 bars and longitudinally completely water blocked up to a pressure of 63 bars. These cables are transversally water blocked up to a pressure of 100 bars and longitudinally partially water blocked (all wires are not water blocked) up to a pressure of |
VDE | Verband der Elektrotechnik Elektronik Informationstechnik |
VDE 0815 | Wiring cables for telecommunication and data processing systems part 814 - Testing of cables, wires and flexible cords Continuance of insulation effect under fire conditions |
part 814 - Testing of cables, wires and flexible cords Continuance of insulation effect under fire conditions | |
VDE 0482 | part 267 - Common test methods for cables under fire conditions - Test on gases evolved during combustion of materials from cables |
part 1034 - Measurement of smoke density of cables burning under defined conditions |